Description:
Load Cell Central's LCC-HTC Dual Stud
Mount load cell is supplied with a stud at each end for
easy in-line mounting in ranges from 50 lbs. through 10,000
lbs. These load cells are highly accurate and manufactured
from heat treated 17-4PH stainless steel. The sensing element
incorporates bonded foil strain gages of the highest quality,
and are sealed for protection against most industrial environments.
Capacities: (lb) 50, 100,
200, 500, 1K, 2K, 2.5K, 5K, 8K, 10K lbs
Dimensions:

Specifications:
Output : 2mV/V nominal
|
Zero Balance : ±1% of F.S. |
| Nonlinearity : 0.15% of F.S. |
Recommended Excitation : 10V |
| Non-Repeatability : 0.05% of F.S. |
Deflection : 0.002" @ F.S. |
| Hysteresis : 0.15% of F.S. |
Safe Overload : 150% of F.S. |
| Thermal Sensitivity Shift : 0.005% of Load/°F |
Comp.Temp. Range : 60°F to 160°F |
| Thermal Zero Shift : 0.005% of F.S./°F |
Operating Temp. Range : -65°F to 200°F |
| Terminal Resistance : 350 ohms |
|
|